Once the proper motor is selected, understanding the many various control devices available and their uses and limitations becomes an important part related to reliable operation and protection of the motor and the personnel using the motor. Motor Control Topics There are four major motor control topics or categories to consider. Each of these has several subcategories and sometimes the subcategories overlap to some extent. Certain pieces of motor control equipment can accomplish multiple functions from each of the topics or categories.
The four categories include: 1) Starting the Motor Disconnecting Means Across the Line Starting Reduced Voltage Starting 2) Motor Protection Overcurrent Protection Overload Protection Other Protection (voltage, phase, etc) Environment 3) Stopping the Motor Coasting Electrical Braking Mechanical Braking 4) Motor Operational Control Speed Control Reversing Jogging Sequence Control • An understanding of each of these areas is necessary to effectively apply motor control principles and equipment to effectively operate and protect a motor.
All motors must have a control device to start and stop the motor called a “motor controller”. Motor Controller A motor controller is the actual device that energizes and de-energizes the circuit to the motor so that it can start and stop. • Motor controllers may include some or all of the following motor control functions: S S starting, stopping, over-current protection, overload protection, reversing, speed changing, jogging, plugging, sequence control, and pilot light indication.
The Research paper on Biomechanics and Motor Control in Remember the Titans
Case Study: Biomechanics and Motor Control in“Remember the Titans”Both biomechanics and motor control are extremely prevalent subjects in the film “Remember the Titans.” The movie instills the basic principles of kinesiology throughout the entire story line. It is very interesting how each different position on the field is accompanied by its own sub-set of kinesiology, exemplifying the diversity ...
Controllers range from simple to complex and can provide control for one motor, groups of motors, or auxiliary equipment such as brakes, clutches, solenoids, heaters, or other signals. Motor Starter The starting mechanism that energizes the circuit to an induction motor is called the “starter” and must supply the motor with sufficient current to provide adequate starting torque under worst case line voltage and load conditions when the motor is energized. • There are several different types of equipment suitable for use as “motor starters” but only two types of starting methods for induction motors.
Across the Line Starting Reduced Voltage Starting Across the Line Starting of Motors Across the Line starting connects the motor windings/terminals directly to the circuit voltage “across the line” for a “full voltage start”. • • This is the simplest method of starting a motor. (And usually the least expensive).
Motors connected across the line are capable of drawing full in-rush current and developing maximum starting torque to accelerate the load to speed in the shortest possible time. All NEMA induction motors up to 200 horsepower, and many larger ones, can withstand full voltage starts.
The electric distribution system or processing operation may not though, even if the motor will).
• Across the Line Starters 2 There are two different types of common “across the line” starters including 1. Manual Motor Starters 2. magnetic motor Starters Manual Motor Starters A manual motor starter is package consisting of a horsepower rated switch with one set of contacts for each phase and corresponding thermal overload devices to provide motor overload protection. • • • The main advantage of a manual motor starter is lower cost than a magnetic motor starter with equivalent motor protection but less motor control capability.
Manual motor starters are often used for smaller motors – typically fractional horsepower motors but the National Electrical Code allows their use up to 10 Horsepower. Since the switch contacts remain closed if power is removed from the circuit without operating the switch, the motor restarts when power is reapplied which can be a safety concern. They do not allow the use of remote control or auxiliary control equipment like a magnetic starter does. • Figure 26. Manual Starter Magnetic Motor Starters A magnetic motor starter is a package consisting of a contactor capable of opening and closing a set 3 of contacts that energize and de-energize the circuit to the motor along with additional motor overload protection equipment. C • Magnetic starters are used with larger motors (required above 10 horsepower) or where greater motor control is desired. The main element of the magnetic motor starter is the contactor, a set of contacts operated by an electromagnetic coil. S S Energizing the coil causes the contacts (A) to close allowing large currents to be initiated and interrupted by a smaller voltage control signal.
The Term Paper on Automatic Railway Gate Control
Aim of this project is to control the unmanned rail gate automatically using embedded platform. Today often we see news papers very often about the railway accidents happening at un- attended railway gates. Present project is designed to avoid such accidents if implemented in spirit. This project is developed in order to help the INDIAN RAILWAYS in making its present working system a better one, ...
The control voltage need not be the same as the motor supply voltage and is often low voltage allowing start/stop controls to be located remotely from the power circuit. Figure 27. Magnetic Starter • Closing the Start button contact energizes the contactor coil. An auxiliary contact on the contactor is wired to seal in the coil circuit. The contactor de-energizes if the control circuit is interrupted, the Stop button is operated, or if power is lost. The overload contacts are arranged so an overload trip on any phase will cause the contactor to open and de-energize all phases. •
Reduced Voltage Starting of Motors Reduced Voltage Starting connects the motor windings/terminals at lower than normal line voltage during the initial starting period to reduce the inrush current when the motor starts. 4 • Reduced voltage starting may be required when: S S The current in-rush form the motor starting adversely affects the voltage drop on the electrical system. needed to reduce the mechanical “starting shock” on drive-lines and equipment when the motor starts. • • Reducing the voltage reduces the current in-rush to the motor and also reduces the starting torque available when the motor starts.
The Business plan on SWOT Analysis on General Motors
General Motors Company is an American automaker with a diverse vehicle brands, selling over nine million dollars in all over the world. The company is headquartered in Detroit, Michigan. General Motors Company has been doing its business since 1908, and having a long years of experience in manufacturing and branding made them become the world’s second largest automaker. The company and its ...