1) What is the role of 0.25M sucrose as the medium for the fractionation process?
Cold sucrose does not chemically react with cell organelles Due to the density and size of sucrose molecules, it is able to suspend pellets for configuration while providing a solution where the centrifugation can be better balanced Sucrose offers a liquid medium in which less dense fractions can be poured off as supernatant at the end of each centrifugation step. 0.25M sucrose solution is isotonic and therefore inhibits the premature lysis of the mitochondria membranes during the fractionation process (centrifugation)
2) List the major components that are present in (a) pellet P1 and (b) Supernatant S2.
Pellet P1 contains: Whole cells
Cytoskeletons (i.e. plasma membrane) Nuclei
Mitochondria
Supernatant S2 contains: ribosomes
Peroxisomes
Lysosomes
Endoplasmic Reticulum (rough and smooth)
3) Were there any notable differences in the appearance of mitochondrial pellets P2 andP3?
Yes there were notable differences in the appearance of P2 and P3. P3 had a light brown colouration and was more compact whereas P2 had a dark brown creamy colouration.
4) Define the beer lamberts law and briefly explain why absorbance has no units.
In Spectroscopy, Beer-Lambert’s Law describes the quantitative relationship between the absorbance of light energy, the concentration of the sample solution and the length of the path through the sample. This means that the amount of light at a given wavelength which is absorbed by a solution is proportional to the concentration of the solution. Thus: A= εcl
The Essay on Osmosis Of Potatoes In Different Sucrose Solutions
The aim of this experiment is to test whether more water moves out of a potato when it is placed in a sweeter sucrose solution than a potato in a less sweet solution. The hypothesis of the experiment is that we expect more water to move out of the potato placed in the sweet solution than the potato placed in a less sweet solution. Independent variable: concentration of sucrose, concentrations: ...
A – measured absorbance
ε – wavelength dependent molar absorptivity coefficient with units moles per centimetre c- concentration in moles per litre
l- path length in centimetre substituting nits into the above
By substituting units into the above equation:
A= (moles-1 L cm-1) (moles x L-1) (cm)
This would cancel to give: A= no units
5) The molar extinction coefficient of p-nitrophenol at 405nm is 18.8×103 L mol1cm-1. Use this value to calculate the concentration of solution O.
From the results absorbance (A) of p-nitrophenol is 0.819 (no units)
Rearranging c in the formula and then substituting A=0.819 and ε into Beer Lambert’s Law gives:
c = A/ (εl)
c=0.819/ ((18.8 x 10^3) x1)
c= 4.356 x10mol L
6) Plot a graph of absorbance vs. concentration for both dilutions. Which dilution appears to be more accurate? Comment on the spread of values.
By using the following equations to calculate the concentrations of O and the dilutions
ie C1V1=C2V2
where C1 and V1 are the respective concentration and volume of the solution being used C2 and V2 are the respective concentration and volume of the solution being prepared
Rearranging for C2 therefore gives
C2 = (C1V1) / V2
Therefore for Solution O,
C2 = (0.30 x 8) / 40 = 0.060 mM
For Solution X2,
C2 = (0.06 x 1) / 2 = 0.030 mM
For Solution X3,
C2 = (0.06 x 1) / 3 = 0.020 mM
For Solution X4,
C2 = (0.06 x 1) / 4 = 0.015 mM
For Solution X5,
C2 = (0.06 x 1) / 5 = 0.012 mM
From both graphs, a general direct proportional relationship between absorbance and concentration was observed, where an increase in concentration increased the absorbance. This was deduced based on the linear plot. From comparing both graphs, one clear observation can be seen with the deviation of values from the best-fit line where the values obtained using the automatic pipette had less deviation from the best-fit than those obtained using the measuring cylinder. Hence the dilutions made via the automatic pipette were more accurate. Also, on noting calibration errors in the instruments, the automatic pipette had a relatively small error of ±0.005ml while the measuring cylinder had a larger error of ±0.05ml
The Essay on Determination Of Zinc And Nickel Concentration
I. Introduction In this experiment, the zinc and nickel contents of unknowns were tested using two methods. In the first method, nickel and zinc were separated through ion-exchange chromatography and analyzed through chelometric titration. In the second method, the unknown was analyzed through the atomic absorption spectroscopy (AAS) of the mixture. In and ion-exchange column, the ions are ...
7)Tabulate the data for the pH measurements. State whether your test solution did or did not exhibit buffering capacity. Explain your observation based on the composition of the solution.
Would not make a good buffer as addition of acid lowered the pH by 1.81 while addition of base lowered the pH by 1.63 C
Would make a good buffering solution as addition of acid only changed the pH by 0.28 while addition of base changed the pH by 0.11. Note that sodium hydroxide lowered the pH in tube 4 and this could have been due to experimenter’s error D
Would make a fairly good buffering solution as addition of acid changed the pH by 0.33 while the addition of base changed the pH by 0.46 Table 2 showing solutions A to D and the corresponding inference.
8) List the major buffer systems in the blood of mammals
Such major systems are
The Carbonic Acid-Bicarbonate buffer
Phosphate buffer
Haemoglobin buffer
Reference:
Harper’s Illustrated Biochemistry 27th Edition