A transformer is a device that transfers electrical energy from one circuit to another through inductively coupled conductors—the transformer’s coils. A varying current in the first or primary winding creates a varying magnetic flux in the transformer’s core and thus a varying magnetic field through the secondary winding. This varying magnetic field induces a varying electromotive force (EMF), or “voltage”, in the secondary winding. This effect is called mutual induction.
If a load is connected to the secondary, an electric current will flow in the secondary winding and electrical energy will be transferred from the primary circuit through the transformer to the load. In an ideal transformer, the induced voltage in the secondary winding (Vs) is in proportion to the primary voltage (Vp), and is given by the ratio of the number of turns in the secondary (Ns) to the number of turns in the primary (Np) as follows:
By appropriate selection of the ratio of turns, a transformer thus allows an alternating current (AC) voltage to be “stepped up” by making Ns greater than Np, or “stepped down” by making Ns less than Np.
In the vast majority of transformers, the windings are coils wound around a ferromagnetic core, air-core transformers being a notable exception.
Transformers range in size from a thumbnail-sized coupling transformer hidden inside a stage microphone to huge units weighing hundreds of tons used to interconnect portions of power grids. All operate with the same basic principles, although the range of designs is wide. While new technologies have eliminated the need for transformers in some electronic circuits, transformers are still found in nearly all electronic devices designed for household (“mains”) voltage. Transformers are essential for high-voltage electric power transmission, which makes long-distance transmission economically practical
The Essay on Primary and Secondary Education in the Netherlands and China
In the Dutch education system one ought to have 12 years of education, starting at the primary school from the age of 4. After 8 years of primary education the children will do a CITO-test that determines to which level of secondary education they can attend. The Dutch secondary education consists of three levels, respectively: VMBO, HAVO and VWO. VMBO is a 4 year program that has a more practical ...
History
[edit]Discovery
Faraday’s experiment with induction between coils of wire [1]
The phenomenon of electromagnetic induction was discovered independently by Michael Faraday and Joseph Henry in 1831. However, Faraday was the first to publish the results of his experiments and thus receive credit for the discovery.[2] The relationship between electromotive force (EMF) or “voltage” and magnetic flux was formalized in an equation now referred to as “Faraday’s law of induction”:
.
where is the magnitude of the EMF in volts and ΦB is the magnetic flux through the circuit (in webers).[3]
Faraday performed the first experiments on induction between coils of wire, including winding a pair of coils around an iron ring, thus creating the first toroidal closed-core transformer.[4]
[edit]Induction coils
Faraday’s ring transformer
The first type of transformer to see wide use was the induction coil, invented by Rev. Nicholas Callan of Maynooth College, Ireland in 1836. He was one of the first researchers to realize that the more turns the secondary winding has in relation to the primary winding, the larger is the increase in EMF. Induction coils evolved from scientists’ and inventors’ efforts to get higher voltages from batteries. Since batteries produce direct current (DC) rather than alternating current (AC), induction coils relied upon vibrating electrical contacts that regularly interrupted the current in the primary to create the flux changes necessary for induction. Between the 1830s and the 1870s, efforts to build better induction coils, mostly by trial and error, slowly revealed the basic principles of transformers.
By the 1870s, efficient generators that produced alternating current (alternators) were available, and it was found that alternating current could power an induction coil directly, without an interrupter. In 1876, Russian engineer Pavel Yablochkov invented a lighting system based on a set of induction coils where the primary windings were connected to a source of alternating current and the secondary windings could be connected to several “electric candles” (arc lamps) of his own design.[5][6] The coils Yablochkov employed functioned essentially as transformers.[5]
The Essay on Transformers
... of coil that are used when dealing with low voltage are iron/steel cores and air core. The core decides on the efficiancy of the transformer. There ... anyone that is interested in learning about transformers. The operation of a transformer depends upon electromagnetic induction. Transformers consist of two sets of wire ...
In 1878, the Ganz Company in Hungary began manufacturing equipment for electric lighting and, by 1883, had installed over fifty systems in Austria-Hungary. Their systems used alternating current exclusively and included those comprising both arc and incandescent lamps, along with generators and other equipment.[7]
Lucien Gaulard and John Dixon Gibbs first exhibited a device with an open iron core called a “secondary generator” in London in 1882, then sold the idea to the Westinghouse company in the United States.[8] They also exhibited the invention in Turin, Italy in 1884, where it was adopted for an electric lighting system.[9] However, the efficiency of their open-core bipolar apparatus remained very low.[10]
Induction coils with open magnetic circuits are inefficient for transfer of power to loads. Until about 1880, the paradigm for AC power transmission from a high voltage supply to a low voltage load was a series circuit. Open-core transformers with a ratio near 1:1 were connected with their primaries in series to allow use of a high voltage for transmission while presenting a low voltage to the lamps. The inherent flaw in this method was that turning off a single lamp affected the voltage supplied to all others on the same circuit. Many adjustable transformer designs were introduced to compensate for this problematic characteristic of the series circuit, including those employing methods of adjusting the core or bypassing the magnetic flux around part of a coil.[11]
Efficient, practical transformer designs did not appear until the 1880s, but within a decade the transformer would be instrumental in the “War of Currents”, and in seeing AC distribution systems triumph over their DC counterparts, a position in which they have remained dominant ever since.[12]
The Homework on An Alternative Program For A Secondary School Introduction
An Alternative Program for a Secondary School. Introduction. Modern secondary school faces a great amount of problems which require precise and thorough investigation and application of different including alternative methods of solution. Potential dropping out. According to School Improvement Research Series (1995), dropping out from school is a complex social problem. In 1993 National Education ...
[edit]Closed-core transformers and the introduction of parallel connection
Drawing of Ganz Company’s 1885 prototype. Capacity: 1400 VA, frequency: 40 Hz, voltage ratio: 120/72 V
Prototypes of the world’s first high-efficiency transformers. They were built by the Z.B.D. team on 16th September 1884.[13]
In the autumn of 1884,[14] Ganz Company engineers Károly Zipernowsky, Ottó Bláthy and Miksa Déri had determined that open-core devices were impracticable, as they were incapable of reliably regulating voltage. In their joint patent application for the “Z.B.D.” transformers, they described two designs with closed magnetic circuits: the “closed-core” and “shell-core” transformers. In the closed-core, the primary and secondary windings were wound around a closed iron ring; in the shell-core, the windings were passed through the iron core. In both designs, the magnetic flux linking the primary and secondary windings traveled almost entirely within the iron core, with no intentional path through air. The new Z.B.D. transformers reached 98 percent efficiency, which was 3.4 times higher than the open core bipolar devices of Gaulard and Gibbs.[15] The patent has also included a claim for the usage of their invention in parallel consumer supply and distribution systems.[16] When they employed it in parallel connected electric distribution systems, closed-core transformers finally made it technically and economically feasible to provide electric power for lighting in homes, businesses and public spaces.[17][18] Bláthy had suggested the use of closed-cores, Zipernowsky the use of shunt connections, and Déri had performed the experiments;[19] Bláthy also discovered the transformer formula, Vs/Vp = Ns/Np.[citation needed] The vast majority of transformers in use today rely on the basic principles discovered by the three engineers. They also reportedly popularized the word “transformer” to describe a device for altering the EMF of an electric current,[17][20] although the term had already been in use by 1882.[21][22] In 1886, the Ganz Company installed the world’s first power station that used AC generators to power a parallel-connected common electrical network, the steam-powered Rome-Cerchi power plant.[23]
The Term Paper on Management of Primary and Secondary Education in Nigeria
Introduction There is no gainsaying the fact that education is very vital to the pace of social, political and economic development of any nation. This is why most nations of the world strive to devote a sizeable proportion of their Gross National Income to develop the educational sector. In Nigeria, between 7. 6% and 9. 9% of our annual expenditure is devoted to education. Management of primary ...
Stanley’s 1886 design for adjustable gap open-core induction coils[24]
Although George Westinghouse had bought Gaulard and Gibbs’ patents in 1885, the Edison Electric Light Company held an option on the U.S. rights for the Z.B.D. transformers, requiring Westinghouse to pursue alternative designs on the same principles. He assigned to William Stanley the task of developing a device for commercial use in United States.[25] Stanley’s first patented design was for induction coils with single cores of soft iron and adjustable gaps to regulate the EMF present in the secondary winding. (See drawing at left.)[24] This design was first used commercially in the U.S. in 1886.[12] But Westinghouse soon had his team working on a design whose core comprised a stack of thin “E-shaped” iron plates, separated individually or in pairs by thin sheets of paper or other insulating material. Prewound copper coils could then be slid into place, and straight iron plates laid in to create a closed magnetic circuit. Westinghouse applied for a patent for the new design in December 1886; it was granted in July 1887.[19][26]
[edit]Other early transformers
In 1889, Russian-born engineer Mikhail Dolivo-Dobrovolsky developed the first three-phase transformer at the Allgemeine Elektricitäts-Gesellschaft (“General Electricity Company”) in Germany.[27]
In 1891, Nikola Tesla invented the Tesla coil, an air-cored, dual-tuned resonant transformer for generating very high voltages at high frequency.[28][29]
Audio frequency transformers (“repeating coils”) were used by early experimenters in the development of the telephone.[citation needed]
[edit]Basic principles
The transformer is based on two principles: first, that an electric current can produce a magnetic field (electromagnetism), and, second that a changing magnetic field within a coil of wire induces a voltage across the ends of the coil (electromagnetic induction).
Changing the current in the primary coil changes the magnetic flux that is developed. The changing magnetic flux induces a voltage in the secondary coil.
An ideal transformer. The secondary current arises from the action of the secondary EMF on the (not shown) load impedance.
The Term Paper on Relationship Between The Current And Voltage
Aim: To investigate the relationship between Current and Voltage Scientific Knowledge The current and voltage of an electric circuit, is given by the formula V = IR. This is known as Ohms. Ohms Law is only applicable, when the temperature of the resistor is kept constant. Therefore Ohms law is only applicable to Ohmic conductors. An example of Ohmic conductors are metals and alloys at constant ...
An ideal transformer is shown in the adjacent figure. Current passing through the primary coil creates a magnetic field. The primary and secondary coils are wrapped around a core of very high magnetic permeability, such as iron, so that most of the magnetic flux passes through both the primary and secondary coils. If a load is connected to the secondary winding, the load current and voltage will be in the directions indicated, given the primary current and voltage in the directions indicated (each will be alternating current in practice).
[edit]Induction law
The voltage induced across the secondary coil may be calculated from Faraday’s law of induction, which states that:
where Vs is the instantaneous voltage, Ns is the number of turns in the secondary coil and Φ is the magnetic flux through one turn of the coil. If the turns of the coil are oriented perpendicular to the magnetic field lines, the flux is the product of the magnetic flux density B and the area A through which it cuts. The area is constant, being equal to the cross-sectional area of the transformer core, whereas the magnetic field varies with time according to the excitation of the primary. Since the same magnetic flux passes through both the primary and secondary coils in an ideal transformer,[30] the instantaneous voltage across the primary winding equals
Taking the ratio of the two equations for Vs and Vp gives the basic equation[31] for stepping up or stepping down the voltage
Np/Ns is known as the turns ratio, and is the primary functional characteristic of any transformer. In the case of step-up transformers, this may sometimes be stated as the reciprocal, Ns/Np. Turns ratio is commonly expressed as an irreducible fraction or ratio: for example, a transformer with primary and secondary windings of, respectively, 100 and 150 turns is said to have a turns ratio of 2:3 rather than 0.667 or 100:150.
[edit]Ideal power equation
The ideal transformer as a circuit element
If the secondary coil is attached to a load that allows current to flow, electrical power is transmitted from the primary circuit to the secondary circuit. Ideally, the transformer is perfectly efficient; all the incoming energy is transformed from the primary circuit to the magnetic field and into the secondary circuit. If this condition is met, the incoming electric power must equal the outgoing power:
The Term Paper on Metering Transformers
n electric power installations metering transformers are used extensively for monitoring voltages and currents. A POTENTIAL transformer, sometimes called PT, is used to monitor a power line voltage. A CURRENT transformers, sometimes called CT, is used to monitor a power line current delivered to a load. Transformers are also used in many other non-metering applications. An electrical transformer ...
giving the ideal transformer equation
Transformers normally have high efficiency, so this formula is a reasonable approximation.
If the voltage is increased, then the current is decreased by the same factor. The impedance in one circuit is transformed by the square of the turns ratio.[30] For example, if an impedance Zs is attached across the terminals of the secondary coil, it appears to the primary circuit to have an impedance of (Np/Ns)2Zs. This relationship is reciprocal, so that the impedance Zp of the primary circuit appears to the secondary to be (Ns/Np)2Zp.
[edit]Detailed operation
The simplified description above neglects several practical factors, in particular the primary current required to establish a magnetic field in the core, and the contribution to the field due to current in the secondary circuit.
Models of an ideal transformer typically assume a core of negligible reluctance with two windings of zero resistance.[32] When a voltage is applied to the primary winding, a small current flows, driving flux around the magnetic circuit of the core.[32] The current required to create the flux is termed the magnetizing current; since the ideal core has been assumed to have near-zero reluctance, the magnetizing current is negligible, although still required to create the magnetic field.
The changing magnetic field induces an electromotive force (EMF) across each winding.[33] Since the ideal windings have no impedance, they have no associated voltage drop, and so the voltages VP and VS measured at the terminals of the transformer, are equal to the corresponding EMFs. The primary EMF, acting as it does in opposition to the primary voltage, is sometimes termed the “back EMF”.[34] This is due to Lenz’s law which states that the induction of EMF would always be such that it will oppose development of any such change in magnetic field.
[edit]Practical considerations
[edit]Leakage flux
Leakage flux of a transformer
Main article: Leakage inductance
The ideal transformer model assumes that all flux generated by the primary winding links all the turns of every winding, including itself. In practice, some flux traverses paths that take it outside the windings.[35] Such flux is termed leakage flux, and results in leakage inductance in series with the mutually coupled transformer windings.[34] Leakage results in energy being alternately stored in and discharged from the magnetic fields with each cycle of the power supply. It is not directly a power loss (see “Stray losses” below), but results in inferior voltage regulation, causing the secondary voltage to fail to be directly proportional to the primary, particularly under heavy load.[35] Transformers are therefore normally designed to have very low leakage inductance. Nevertheless, it is impossible to eliminate all leakage flux because it plays an essential part in the operation of the transformer. The combined effect of the leakage flux and the electric field around the windings is what transfers energy from the primary to the secondary.[36]
In some applications increased leakage is desired, and long magnetic paths, air gaps, or magnetic bypass shunts may be deliberately introduced to a transformer’s design to limit the short-circuit current it will supply.[34] Leaky transformers may be used to supply loads that exhibit negative resistance, such as electric arcs, mercury vapor lamps, and neon signs; or for safely handling loads that become periodically short-circuited such as electric arc welders.[37]
Air gaps are also used to keep a transformer from saturating, especially audio-frequency transformers in circuits that have a direct current flowing through the windings.[38]
Leakage inductance is also helpful when transformers are operated in parallel. It can be shown that if the “per-unit” inductance of two transformers is the same (a typical value is 5%), they will automatically split power “correctly” (e.g. 500 kVA unit in parallel with 1,000 kVA unit, the larger one will carry twice the current).[citation needed]
[edit]Effect of frequency
Transformer universal EMF equation
If the flux in the core is purely sinusoidal, the relationship for either winding between its rms voltage Erms of the winding, and the supply frequency f, number of turns N, core cross-sectional area a and peak magnetic flux density B is given by the universal EMF equation:[32]
If the flux does not contain even harmonics the following equation can be used for half-cycle average voltage Eavg of any waveshape:
The time-derivative term in Faraday’s Law shows that the flux in the core is the integral with respect to time of the applied voltage.[39] Hypothetically an ideal transformer would work with direct-current excitation, with the core flux increasing linearly with time.[40] In practice, the flux would rise to the point where magnetic saturation of the core occurs, causing a huge increase in the magnetizing current and overheating the transformer. All practical transformers must therefore operate with alternating (or pulsed) current.[40]
The EMF of a transformer at a given flux density increases with frequency.[32] By operating at higher frequencies, transformers can be physically more compact because a given core is able to transfer more power without reaching saturation and fewer turns are needed to achieve the same impedance. However, properties such as core loss and conductor skin effect also increase with frequency. Aircraft and military equipment employ 400 Hz power supplies which reduce core and winding weight.[41] Conversely, frequencies used for some railway electrification systems were much lower (e.g. 16.7 Hz and 25 Hz) than normal utility frequencies (50 – 60 Hz) for historical reasons concerned mainly with the limitations of early electric traction motors. As such, the transformers used to step down the high over-head line voltages (e.g. 15 kV) are much heavier for the same power rating than those designed only for the higher frequencies.
Operation of a transformer at its designed voltage but at a higher frequency than intended will lead to reduced magnetizing current; at lower frequency, the magnetizing current will increase. Operation of a transformer at other than its design frequency may require assessment of voltages, losses, and cooling to establish if safe operation is practical. For example, transformers may need to be equipped with “volts per hertz” over-excitation relays to protect the transformer from overvoltage at higher than rated frequency.
One example of state-of-the-art design is those transformers used for electric multiple unit high speed trains, particularly those required to operate across the borders of countries using different standards of electrification. The position of such transformers is restricted to being hung below the passenger compartment. They have to function at different frequencies (down to 16.7 Hz) and voltages (up to 25 kV) whilst handling the enhanced power requirements needed for operating the trains at high speed.
Knowledge of natural frequencies of transformer windings is of importance for the determination of the transient response of the windings to impulse and switching surge voltages.
[edit]Energy losses
An ideal transformer would have no energy losses, and would be 100% efficient. In practical transformers energy is dissipated in the windings, core, and surrounding structures. Larger transformers are generally more efficient, and those rated for electricity distribution usually perform better than 98%.[42]
Experimental transformers using superconducting windings achieve efficiencies of 99.85%.[43] The increase in efficiency can save considerable energy, and hence money, in a large heavily loaded transformer; the trade-off is in the additional initial and running cost of the superconducting design.
Losses in transformers (excluding associated circuitry) vary with load current, and may be expressed as “no-load” or “full-load” loss. Winding resistance dominates load losses, whereas hysteresis and eddy currents losses contribute to over 99% of the no-load loss. The no-load loss can be significant, so that even an idle transformer constitutes a drain on the electrical supply and a running cost; designing transformers for lower loss requires a larger core, good-quality silicon steel, or even amorphous steel, for the core, and thicker wire, increasing initial cost, so that there is a trade-off between initial cost and running cost. (Also see energy efficient transformer).[44]
Transformer losses are divided into losses in the windings, termed copper loss, and those in the magnetic circuit, termed iron loss. Losses in the transformer arise from:
Winding resistance
Current flowing through the windings causes resistive heating of the conductors. At higher frequencies, skin effect and proximity effect create additional winding resistance and losses.
Hysteresis losses
Each time the magnetic field is reversed, a small amount of energy is lost due to hysteresis within the core. For a given core material, the loss is proportional to the frequency, and is a function of the peak flux density to which it is subjected.[44]
Eddy currents
Ferromagnetic materials are also good conductors, and a core made from such a material also constitutes a single short-circuited turn throughout its entire length. Eddy currents therefore circulate within the core in a plane normal to the flux, and are responsible for resistive heating of the core material. The eddy current loss is a complex function of the square of supply frequency and inverse square of the material thickness.[44] Eddy current losses can be reduced by making the core of a stack of plates electrically insulated from each other, rather than a solid block; all transformers operating at low frequencies use laminated or similar cores.
Magnetostriction
Magnetic flux in a ferromagnetic material, such as the core, causes it to physically expand and contract slightly with each cycle of the magnetic field, an effect known as magnetostriction. This produces the buzzing sound commonly associated with transformers,[31] and can cause losses due to frictional heating.
Mechanical losses
In addition to magnetostriction, the alternating magnetic field causes fluctuating forces between the primary and secondary windings. These incite vibrations within nearby metalwork, adding to the buzzing noise, and consuming a small amount of power.[45]
Stray losses
Leakage inductance is by itself largely lossless, since energy supplied to its magnetic fields is returned to the supply with the next half-cycle. However, any leakage flux that intercepts nearby conductive materials such as the transformer’s support structure will give rise to eddy currents and be converted to heat.[46] There are also radiative losses due to the oscillating magnetic field, but these are usually small.
[edit]Dot convention
Main article: Dot convention
It is common in transformer schematic symbols for there to be a dot at the end of each coil within a transformer, particularly for transformers with multiple primary and secondary windings. The dots indicate the direction of each winding relative to the others. Voltages at the dot end of each winding are in phase; current flowing into the dot end of a primary coil will result in current flowing out of the dot end of a secondary coil.
[edit]Equivalent circuit
Refer to the diagram below
The physical limitations of the practical transformer may be brought together as an equivalent circuit model (shown below) built around an ideal lossless transformer.[47] Power loss in the windings is current-dependent and is represented as in-series resistances Rp and Rs. Flux leakage results in a fraction of the applied voltage dropped without contributing to the mutual coupling, and thus can be modeled as reactances of each leakage inductance Xp and Xs in series with the perfectly coupled region.
Iron losses are caused mostly by hysteresis and eddy current effects in the core, and are proportional to the square of the core flux for operation at a given frequency.[48] Since the core flux is proportional to the applied voltage, the iron loss can be represented by a resistance RC in parallel with the ideal transformer.
A core with finite permeability requires a magnetizing current Im to maintain the mutual flux in the core. The magnetizing current is in phase with the flux; saturation effects cause the relationship between the two to be non-linear, but for simplicity this effect tends to be ignored in most circuit equivalents.[48] With a sinusoidal supply, the core flux lags the induced EMF by 90° and this effect can be modeled as a magnetizing reactance (reactance of an effective inductance) Xm in parallel with the core loss component. Rc and Xm are sometimes together termed the magnetizing branch of the model. If the secondary winding is made open-circuit, the current I0 taken by the magnetizing branch represents the transformer’s no-load current.[47]
The secondary impedance Rs and Xs is frequently moved (or “referred”) to the primary side after multiplying the components by the impedance scaling factor (Np/Ns)2.
Transformer equivalent circuit, with secondary impedances referred to the primary side
The resulting model is sometimes termed the “exact equivalent circuit”, though it retains a number of approximations, such as an assumption of linearity.[47] Analysis may be simplified by moving the magnetizing branch to the left of the primary impedance, an implicit assumption that the magnetizing current is low, and then summing primary and referred secondary impedances, resulting in so-called equivalent impedance.
The parameters of equivalent circuit of a transformer can be calculated from the results of two transformer tests: open-circuit test and short-circuit test.
[edit]Types
For more details on this topic, see Transformer types.
A wide variety of transformer designs are used for different applications, though they share several common features. Important common transformer types include:
Autotransforme
Autotransformer
A variable autotransformer
In an autotransformer portions of the same winding act as both the primary and secondary. The winding has at least three taps where electrical connections are made. An autotransformer can be smaller, lighter and cheaper than a standard dual-winding transformer however the autotransformer does not provide electrical isolation.
Autotransformers are often used to step up or down between voltages in the 110-117-120 volt range and voltages in the 220-230-240 volt range, e.g., to output either 110 or 120V (with taps) from 230V input, allowing equipment from a 100 or 120V region to be used in a 230V region.
A variable autotransformer is made by exposing part of the winding coils and making the secondary connection through a sliding brush, giving a variable turns ratio.[49] Such a device is often referred to by the trademark name Variac.
[edit]Polyphase transformers
For more details on this topic, see Three-phase electric power.
Three-phase step-down transformer mounted between two utility poles
For three-phase supplies, a bank of three individual single-phase transformers can be used, or all three phases can be incorporated as a single three-phase transformer. In this case, the magnetic circuits are connected together, the core thus containing a three-phase flow of flux.[50] A number of winding configurations are possible, giving rise to different attributes and phase shifts.[51] One particular polyphase configuration is the zigzag transformer, used for grounding and in the suppression of harmonic currents.[52]
Screenshot of a FEM simulation of the magnetic flux inside a three-phase power transformer (full animation)
[edit]Leakage transformers
Leakage transformer
A leakage transformer, also called a stray-field transformer, has a significantly higher leakage inductance than other transformers, sometimes increased by a magnetic bypass or shunt in its core between primary and secondary, which is sometimes adjustable with a set screw. This provides a transformer with an inherent current limitation due to the loose coupling between its primary and the secondary windings. The output and input currents are low enough to prevent thermal overload under all load conditions—even if the secondary is shorted.
Leakage transformers are used for arc welding and high voltage discharge lamps (neon lights and cold cathode fluorescent lamps, which are series-connected up to 7.5 kV AC).
It acts then both as a voltage transformer and as a magnetic ballast.
Other applications are short-circuit-proof extra-low voltage transformers for toys or doorbell installations.
[edit]Resonant transformers
For more details on this topic, see Resonant inductive coupling.
A resonant transformer is a kind of leakage transformer. It uses the leakage inductance of its secondary windings in combination with external capacitors, to create one or more resonant circuits. Resonant transformers such as the Tesla coil can generate very high voltages, and are able to provide much higher current than electrostatic high-voltage generation machines such as the Van de Graaff generator.[53] One of the applications of the resonant transformer is for the CCFL inverter. Another application of the resonant transformer is to couple between stages of a superheterodyne receiver, where the selectivity of the receiver is provided by tuned transformers in the intermediate-frequency amplifiers.[54]
[edit]Audio transformers
Audio transformers are those specifically designed for use in audio circuits. They can be used to block radio frequency interference or the DC component of an audio signal, to split or combine audio signals, or to provide impedance matching between high and low impedance circuits, such as between a high impedance tube (valve) amplifier output and a low impedance loudspeaker, or between a high impedance instrument output and the low impedance input of a mixing console.
Such transformers were originally designed to connect different telephone systems to one another while keeping their respective power supplies isolated, and are still commonly used to interconnect professional audio systems or system components.
Being magnetic devices, audio transformers are susceptible to external magnetic fields such as those generated by AC current-carrying conductors. “Hum” is a term commonly used to describe unwanted signals originating from the “mains” power supply (typically 50 or 60 Hz).
Audio transformers used for low-level signals, such as those from microphones, often include shielding to protect against extraneous magnetically coupled signals.
[edit]Instrument transformers
Instrument transformers are used for measuring voltage and current in electrical power systems, and for power system protection and control. Where a voltage or current is too large to be conveniently used by an instrument, it can be scaled down to a standardized, low value. Instrument transformers isolate measurement, protection and control circuitry from the high currents or voltages present on the circuits being measured or controlled.
Current transformers, designed for placing around conductors
A current transformer is a transformer designed to provide a current in its secondary coil proportional to the current flowing in its primary coil.[55]
Voltage transformers (VTs), also referred to as “potential transformers” (PTs), are designed to have an accurately known transformation ratio in both magnitude and phase, over a range of measuring circuit impedances. A voltage transformer is intended to present a negligible load to the supply being measured. The low secondary voltage allows protective relay equipment and measuring instruments to be operated at a lower voltages.[56]
Both current and voltage instrument transformers are designed to have predictable characteristics on overloads. Proper operation of over-current protective relays requires that current transformers provide a predictable transformation ratio even during a short-circuit.
[edit]Classification
Transformers can be considered a class of electric machine with no moving parts; as such they are described as static electric machines. They can be classified in many different ways; an incomplete list is:
By power capacity: from a fraction of a volt-ampere (VA) to over a thousand MVA;
By frequency range: power-, audio-, or radio frequency;
By voltage class: from a few volts to hundreds of kilovolts;
By cooling type: air-cooled, oil-filled, fan-cooled, or water-cooled;
By application: such as power supply, impedance matching, output voltage and current stabilizer, or circuit isolation;
By purpose: distribution, rectifier, arc furnace, amplifier output, etc.;
By winding turns ratio: step-up, step-down, isolating with equal or near-equal ratio, variable, multiple windings.
[edit]Construction
[edit]Cores
Laminated core transformer showing edge of laminations at top of photo
[edit]Laminated steel cores
Transformers for use at power or audio frequencies typically have cores made of high permeability silicon steel.[57] The steel has a permeability many times that of free space, and the core thus serves to greatly reduce the magnetizing current, and confine the flux to a path which closely couples the windings.[58] Early transformer developers soon realized that cores constructed from solid iron resulted in prohibitive eddy-current losses, and their designs mitigated this effect with cores consisting of bundles of insulated iron wires.[8] Later designs constructed the core by stacking layers of thin steel laminations, a principle that has remained in use. Each lamination is insulated from its neighbors by a thin non-conducting layer of insulation.[50] The universal transformer equation indicates a minimum cross-sectional area for the core to avoid saturation.
The effect of laminations is to confine eddy currents to highly elliptical paths that enclose little flux, and so reduce their magnitude. Thinner laminations reduce losses,[57] but are more laborious and expensive to construct.[59] Thin laminations are generally used on high frequency transformers, with some types of very thin steel laminations able to operate up to 10 kHz.
Laminating the core greatly reduces eddy-current losses
One common design of laminated core is made from interleaved stacks of E-shaped steel sheets capped with I-shaped pieces, leading to its name of “E-I transformer”.[59] Such a design tends to exhibit more losses, but is very economical to manufacture. The cut-core or C-core type is made by winding a steel strip around a rectangular form and then bonding the layers together. It is then cut in two, forming two C shapes, and the core assembled by binding the two C halves together with a steel strap.[59] They have the advantage that the flux is always oriented parallel to the metal grains, reducing reluctance.
A steel core’s remanence means that it retains a static magnetic field when power is removed. When power is then reapplied, the residual field will cause a high inrush current until the effect of the remaining magnetism is reduced, usually after a few cycles of the applied alternating current.[60] Overcurrent protection devices such as fuses must be selected to allow this harmless inrush to pass. On transformers connected to long, overhead power transmission lines, induced currents due to geomagnetic disturbances during solar storms can cause saturation of the core and operation of transformer protection devices.[61]
Distribution transformers can achieve low no-load losses by using cores made with low-loss high-permeability silicon steel or amorphous (non-crystalline) metal alloy. The higher initial cost of the core material is offset over the life of the transformer by its lower losses at light load.[62]
[edit]Solid cores
Powdered iron cores are used in circuits (such as switch-mode power supplies) that operate above main frequencies and up to a few tens of kilohertz. These materials combine high magnetic permeability with high bulk electrical resistivity. For frequencies extending beyond the VHF band, cores made from non-conductive magnetic ceramic materials called ferrites are common.[59] Some radio-frequency transformers also have movable cores (sometimes called ‘slugs’) which allow adjustment of the coupling coefficient (and bandwidth) of tuned radio-frequency circuits.
[edit]Toroidal cores
Small toroidal core transformer
Toroidal transformers are built around a ring-shaped core, which, depending on operating frequency, is made from a long strip of silicon steel or permalloy wound into a coil, powdered iron, or ferrite.[63] A strip construction ensures that the grain boundaries are optimally aligned, improving the transformer’s efficiency by reducing the core’s reluctance. The closed ring shape eliminates air gaps inherent in the construction of an E-I core.[37] The cross-section of the ring is usually square or rectangular, but more expensive cores with circular cross-sections are also available. The primary and secondary coils are often wound concentrically to cover the entire surface of the core. This minimizes the length of wire needed, and also provides screening to minimize the core’s magnetic field from generating electromagnetic interference.
Toroidal transformers are more efficient than the cheaper laminated E-I types for a similar power level. Other advantages compared to E-I types, include smaller size (about half), lower weight (about half), less mechanical hum (making them superior in audio amplifiers), lower exterior magnetic field (about one tenth), low off-load losses (making them more efficient in standby circuits), single-bolt mounting, and greater choice of shapes. The main disadvantages are higher cost and limited power capacity (see “Classification” above).
Because of the lack of a residual gap in the magnetic path, toroidal transformers also tend to exhibit higher inrush current, compared to laminated E-I types.
Ferrite toroidal cores are used at higher frequencies, typically between a few tens of kilohertz to hundreds of megahertz, to reduce losses, physical size, and weight of a switched-mode power supply. A drawback of toroidal transformer construction is the higher labor cost of winding. This is because it is necessary to pass the entire length of a coil winding through the core aperture each time a single turn is added to the coil. As a consequence, toroidal transformers are uncommon above ratings of a few kVA. Small distribution transformers may achieve some of the benefits of a toroidal core by splitting it and forcing it open, then inserting a bobbin containing primary and secondary windings.
[edit]Air cores
A physical core is not an absolute requisite and a functioning transformer can be produced simply by placing the windings near each other, an arrangement termed an “air-core” transformer. The air which comprises the magnetic circuit is essentially lossless, and so an air-core transformer eliminates loss due to hysteresis in the core material.[34] The leakage inductance is inevitably high, resulting in very poor regulation, and so such designs are unsuitable for use in power distribution.[34] They have however very high bandwidth, and are frequently employed in radio-frequency applications,[64] for which a satisfactory coupling coefficient is maintained by carefully overlapping the primary and secondary windings. They’re also used for resonant transformers such as Tesla coils where they can achieve reasonably low loss in spite of the high leakage inductance.
[edit]Windings
Windings are usually arranged concentrically to minimize flux leakage.
Cut view through transformer windings. White: insulator. Green spiral: Grain oriented silicon steel. Black: Primary winding made of oxygen-free copper. Red: Secondary winding. Top left: Toroidal transformer. Right: C-core, but E-core would be similar. The black windings are made of film. Top: Equally low capacitance between all ends of both windings. Since most cores are at least moderately conductive they also need insulation. Bottom: Lowest capacitance for one end of the secondary winding needed for low-power high-voltage transformers. Bottom left: Reduction of leakage inductance would lead to increase of capacitance.
The conducting material used for the windings depends upon the application, but in all cases the individual turns must be electrically insulated from each other to ensure that the current travels throughout every turn.[39] For small power and signal transformers, in which currents are low and the potential difference between adjacent turns is small, the coils are often wound from enamelled magnet wire, such as Formvar wire. Larger power transformers operating at high voltages may be wound with copper rectangular strip conductors insulated by oil-impregnated paper and blocks of pressboard.[65]
High-frequency transformers operating in the tens to hundreds of kilohertz often have windings made of braided Litz wire to minimize the skin-effect and proximity effect losses.[39] Large power transformers use multiple-stranded conductors as well, since even at low power frequencies non-uniform distribution of current would otherwise exist in high-current windings.[65] Each strand is individually insulated, and the strands are arranged so that at certain points in the winding, or throughout the whole winding, each portion occupies different relative positions in the complete conductor. The transposition equalizes the current flowing in each strand of the conductor, and reduces eddy current losses in the winding itself. The stranded conductor is also more flexible than a solid conductor of similar size, aiding manufacture.[65]
For signal transformers, the windings may be arranged in a way to minimize leakage inductance and stray capacitance to improve high-frequency response. This can be done by splitting up each coil into sections, and those sections placed in layers between the sections of the other winding. This is known as a stacked type or interleaved winding.
Both the primary and secondary windings on power transformers may have external connections, called taps, to intermediate points on the winding to allow selection of the voltage ratio. In distribution transformers the taps may be connected to an automatic on-load tap changer for voltage regulation of distribution circuits. Audio-frequency transformers, used for the distribution of audio to public address loudspeakers, have taps to allow adjustment of impedance to each speaker. A center-tapped transformer is often used in the output stage of an audio power amplifier in a push-pull circuit. Modulation transformers in AM transmitters are very similar.
Certain transformers have the windings protected by epoxy resin. By impregnating the transformer with epoxy under a vacuum, one can replace air spaces within the windings with epoxy, thus sealing the windings and helping to prevent the possible formation of corona and absorption of dirt or water. This produces transformers more suited to damp or dirty environments, but at increased manufacturing cost.[66]
[edit]Coolant
Cut-away view of three-phase oil-cooled transformer. The oil reservoir is visible at the top. Radiative fins aid the dissipation of heat.
High temperatures will damage the winding insulation.[67] Small transformers do not generate significant heat and are cooled by air circulation and radiation of heat. Power transformers rated up to several hundred kVA can be adequately cooled by natural convective air-cooling, sometimes assisted by fans.[68] In larger transformers, part of the design problem is removal of heat. Some power transformers are immersed in transformer oil that both cools and insulates the windings.[69] The oil is a highly refined mineral oil that remains stable at transformer operating temperature. Indoor liquid-filled transformers are required by building regulations in many jurisdictions to use a non-flammable liquid, or to be located in fire-resistant rooms.[70] Air-cooled dry transformers are preferred for indoor applications even at capacity ratings where oil-cooled construction would be more economical, because their cost is offset by the reduced building construction cost.
The oil-filled tank often has radiators through which the oil circulates by natural convection; some large transformers employ forced circulation of the oil by electric pumps, aided by external fans or water-cooled heat exchangers.[69] Oil-filled transformers undergo prolonged drying processes to ensure that the transformer is completely free of water vapor before the cooling oil is introduced. This helps prevent electrical breakdown under load. Oil-filled transformers may be equipped with Buchholz relays, which detect gas evolved during internal arcing and rapidly de-energize the transformer to avert catastrophic failure.[60] Oil-filled transformers may fail, rupture, and burn, causing power outages and losses. Installations of oil-filled transformers usually includes fire protection measures such as walls, oil containment, and fire-suppression sprinkler systems.
Polychlorinated biphenyls have properties that once favored their use as a coolant, though concerns over their environmental persistence led to a widespread ban on their use.[71] Today, non-toxic, stable silicone-based oils, or fluorinated hydrocarbons may be used where the expense of a fire-resistant liquid offsets additional building cost for a transformer vault.[67][70] Before 1977, even transformers that were nominally filled only with mineral oils may also have been contaminated with polychlorinated biphenyls at 10-20 ppm. Since mineral oil and PCB fluid mix, maintenance equipment used for both PCB and oil-filled transformers could carry over small amounts of PCB, contaminating oil-filled transformers.[72]
Some “dry” transformers (containing no liquid) are enclosed in sealed, pressurized tanks and cooled by nitrogen or sulfur hexafluoride gas.[67]
Experimental power transformers in the 2 MVA range have been built with superconducting windings which eliminates the copper losses, but not the core steel loss. These are cooled by liquid nitrogen or helium.[73]
[edit]Insulation drying
Construction of oil-filled transformers requires that the insulation covering the windings be thoroughly dried before the oil is introduced. There are several different methods of drying. Common for all is that they are carried out in vacuum environment. The vacuum makes it difficult to transfer energy (heat) to the insulation. For this there are several different methods. The traditional drying is done by circulating hot air over the active part and cycle this with periods of vacuum (hot-air vacuum drying, HAV).
More common for larger transformers is to use evaporated solvent which condenses on the colder active part. The benefit is that the entire process can be carried out at lower pressure and without influence of added oxygen. This process is commonly called vapour-phase drying (VPD).
For distribution transformers, which are smaller and have a smaller insulation weight, resistance heating can be used. This is a method where current is injected in the windings to heat the insulation. The benefit is that the heating can be controlled very well and it is energy efficient. The method is called low-frequency heating (LFH) since the current is injected at a much lower frequency than the nominal of the grid, which is normally 50 or 60 Hz. A lower frequency reduces the effect of the inductance in the transformer, so the voltage needed to induce the current can be reduced.[74]
[edit]Terminals
Very small transformers will have wire leads connected directly to the ends of the coils, and brought out to the base of the unit for circuit connections. Larger transformers may have heavy bolted terminals, bus bars or high-voltage insulated bushings made of polymers or porcelain. A large bushing can be a complex structure since it must provide careful control of the electric field gradient without letting the transformer leak oil.[75]
[edit]Applications
Image of an electrical substation in Melbourne, Australia showing 3 of 5 220kV/66kV transformers, each with a capacity of 185MVA
A major application of transformers is to increase voltage before transmitting electrical energy over long distances through wires. Wires have resistance and so dissipate electrical energy at a rate proportional to the square of the current through the wire. By transforming electrical power to a high-voltage (and therefore low-current) form for transmission and back again afterward, transformers enable economical transmission of power over long distances. Consequently, transformers have shaped the electricity supply industry, permitting generation to be located remotely from points of demand.[76] All but a tiny fraction of the world’s electrical power has passed through a series of transformers by the time it reaches the consumer.[46]
Transformers are also used extensively in electronic products to step down the supply voltage to a level suitable for the low voltage circuits they contain. The transformer also electrically isolates the end user from contact with the supply voltage.
Signal and audio transformers are used to couple stages of amplifiers and to match devices such as microphones and record players to the input of amplifiers. Audio transformers allowed telephone circuits to carry on a two-way conversation over a single pair of wires. A balun transformer converts a signal that is referenced to ground to a signal that has balanced voltages to ground, such as between external cables and internal circuits.
The principle of open-circuit (unloaded) transformer is widely used for characterisation of soft magnetic materials, for example in the internationally standardised Epstein frame method.[77]
[edit]
induction motor
An induction or asynchronous motor is a type of AC motor where power is supplied to the rotor by means of electromagnetic induction. These motors are widely used in industrial drives, particularly polyphase induction motors, because they are robust and have no brushes. Their speed can be controlled with a variable frequency drive.
Contents
1 History
2 Operation and comparison to synchronous motors
2.1 Synchronous speed
2.2 Slip
3 Construction
4 Speed control
5 Equivalent circuit
6 Starting
7 Linear induction motor
8 Sources
9 References
10 External links
[edit]History
The idea of a rotating magnetic field was developed by François Arago in 1824,[1] and first implemented by Walter Baily.[2] Based on this, practical induction motors were independently invented by Nikola Tesla in 1883 and Galileo Ferraris in 1885.[3] According to his 1915 autobiography Tesla conceived the rotating magnetic field in 1882 and used it to invent the first induction motor in 1883;[4] Ferraris developed the idea in 1885.[5] In 1888, Ferraris published his research to the Royal Academy of Sciences in Turin, where he detailed the foundations of motor operation;[6] Tesla, in the same year, was granted U.S. Patent 381,968 for his motor. The induction motor with a cage was invented by Mikhail Dolivo-Dobrovolsky a year later.
[edit]Operation and comparison to synchronous motors
A 3-phase power supply provides a rotating magnetic field in an induction motor.
In a synchronous AC motor, the rotating magnetic field of the stator imposes a torque on the magnetic field of the rotor, causing it to rotate steadily. It is called synchronous because at steady state, the speed of the rotor matches the speed of the rotating magnetic field in the stator. By contrast, an induction motor has a current induced in the rotor; to do this, stator windings are arranged so that when energised with a polyphase supply they create a rotating magnetic field that induces current in the rotor conductors. These currents interact with the rotating magnetic field, causing rotational motion of the rotor.
For these currents to be induced, the speed of the physical rotor must be lower than that of the stator’s rotating magnetic field (ns), or the magnetic field would not be moving relative to the rotor conductors and no currents would be induced. If this happens while the motor is operating, the rotor slightly slows down, and consequently a current is induced again. The ratio between the speed of the magnetic field as seen by the rotor (slip speed) and the speed of the stator’s rotating field is unitless and it is called slip. For this reason, induction motors are sometimes referred to as asynchronous motors.[7] An induction motor can be used as induction generator, or it can be unrolled to form the linear induction motor which can directly generate linear motion.
[edit]Synchronous speed
To understand the behaviour of induction motors, it is helpful to understand their distinction from a synchronous motor. A synchronous motor always runs at a shaft rotation frequency that is an integer fraction of the supply frequency; the synchronous speed of an induction motor is the same. It can be shown that ns in rpm is determined by
where f is the frequency of the AC supply in Hz and p is the number of magnetic pole pairs per phase.[8] Some texts refer to the number of pole pairs per phase; a 6 pole motor would have 3 pole pairs. In this case, P, the number of pole pairs, takes the place of p in the equation. For example, a two-pole motor (one pair of poles) would have a synchronous speed of 3600 revolutions per minute at a power frequency of 60 Hz, but at 25 Hz the speed would be only 1500 r/m.
[edit]Slip
Typical torque curve as a function of slip.
The slip s is a ratio relative to the synchronous speed and is defined as
where nr is the rotor rotation speed in rpm.[9]
[edit]Construction
Typical winding pattern for a 3 phase, 4 pole motor (phases here are labelled U, V, W).
Note the interleaving of the pole windings and the resulting quadrupole field.
Squirrel cages were invented by Mikhail Dolivo-Dobrovolsky.
The stator of an induction motor consists of poles carrying supply current to induce a magnetic field that penetrates the rotor. To optimize the distribution of the magnetic field, the windings are distributed in slots around the stator, with the magnetic field having the same number of north and south poles. Induction motors are most commonly run on single-phase or three-phase power, but two-phase motors exist; in theory, induction motors can have any number of phases. Many single-phase motors having two windings and can be viewed as two-phase motors, since a capacitor is used to generate a second power phase 90 degrees from the single-phase supply and feeds it to the second motor winding. Single-phase power is more widely available in residential buildings, but cannot produce a rotating field in the motor, so they must incorporate some kind of starting mechanism to produce a rotating field. There are three types of rotor: squirrel cage rotors made up of skewed (to reduce noise) bars of copper or aluminum that span the length of the rotor, slip ring rotors with windings connected to slip rings replacing the bars of the squirrel cage, and solid core rotors made from mild steel.
[edit]Speed control
Typical torque curves for different line frequencies. By varying the line frequency with an inverter, induction motors can be kept on the stable part of the torque curve above the peak over a wide range of rotation speeds. However, the inverters can be expensive, and fixed line frequencies and other start up schemes are often employed instead.
The theoretical unloaded speed (with slip approaching zero) of the induction motor is controlled by the number of pole pairs and the frequency of the supply voltage.
When driven from a fixed line frequency, loading the motor reduces the rotation speed. When used in this way, induction motors are usually run so that in operation the shaft rotation speed is kept above the peak torque point; then the motor will tend to run at reasonably constant speed. Below this point, the speed tends to be unstable and the motor may stall or run at reduced shaft speed, depending on the nature of the mechanical load.
Before the development of semiconductor power electronics, it was difficult to vary the frequency, and induction motors were mainly used in fixed speed applications. However, many older DC motors have now been replaced with induction motors and accompanying inverters in industrial applications.
[edit]Equivalent circuit
The equivalent circuit of an induction motor.
The equivalent circuit of an induction motor has the equivalent resistance of the stator on the left, consisting of the copper and core resistance in series, as Rs. During operation, the stator induces reactance, represented by the inductor Xs. Xr represents the effect of the rotor passing through the stator’s magnetic field. The effective resistance of the rotor, Rr, is composed of the equivalent value of the machine’s power and the ohmic resistance of the stator windings and squirrel cage.
The induction motor equivalent circuit when idle is approximately Rs + Xs, which is mostly reactive. Induction motors generally have a poor power factor, which can be improved by a compensation network.
The idle current draw is often near the rated current, due to the copper and core losses existing without load. In these conditions, this is usually more than half the power loss at the rated load. If the torque against the motor spindle is increased, the active current in the rotor increases by Rr. Due to the construction of the induction motor, the two resistances induce magnetic flux, in contrast to synchronous machines where it is induced only by the reactive current in the stator windings.
The current produces a voltage drop in the cage factor of Rr and a slightly higher one in the stator windings. Hence, the losses increase faster in the rotor than in the stator. Rs and the copper factor of Rr both cause I2R losses, meaning the efficiency improves with increasing load and reduces with temperature.
Xs gets smaller with smaller frequency and must be reduced by the delivered drive voltage. Thus, increases engine power losses. In continuous operation, this is an approximation because a nominal torque generated by the cooling of the rotor and stator is not included in the calculation. Above the rated speed or frequency, induction motors are more effective at higher voltages. Today, Rs and Rr are measured automatically and thus can be used on a motor to automatically configure itself and thus protect it from overload. Holding torques and speeds close to zero can be achieved with vector controls. There can be problems with cooling here, since the fan is usually mounted on the rotor.[citation needed]
[edit]Starting
Main article: Motor controller
Torque curves for 4 types of asynchronous induction motors:
A) Single-phase motor
B) Polyphase squirrel cage motor
C) Polyphase squirrel cage deep bar motor
D) Polyphase double squirrel cage motor
A single phase induction motor is not self starting; thus, it is necessary to provide a starting circuit and associated start windings to give the initial rotation in a single phase induction motor. The normal running windings within such a motor motor can cause the rotor to turn in either direction, so the starting circuit determines the operating direction.
The four methods of starting an induction motor are direct on-line, reactor, auto-transformer and star-delta. Unlike a wound-rotor motor, the rotor circuit is inaccessible and it is not feasible to introduce extra resistance for starting or speed control.
For small single-phase shaded-pole motor of a few watts, starting is done by a shaded pole, with a turn of copper wire around part of the pole. The current induced in this turn lags behind the supply current, creating a delayed magnetic field around the shaded part of the pole face. This imparts sufficient rotational character to start the motor. These motors are typically used in applications such as desk fans and record players, as the starting torque is very low and efficiency is not a problem.
Larger single phase motors have a second stator winding fed with out-of-phase current; such currents may be created by feeding the winding through a capacitor or having it have different values of inductance and resistance from the main winding. In some designs, the second winding is disconnected once the motor is up to speed, usually either by a centrifugal switch acting on weights on the motor shaft or a thermistor which heats up and increases its resistance, reducing the current through the second winding to an insignificant level. Other designs keep the second winding on when running, improving torque.
Polyphase motors have rotor bars shaped to give different speed/torque characteristics. The current distribution within the rotor bars varies depending on the frequency of the inducted current. At standstill, the rotor current is the same frequency as the stator current, and tends to travel at the outermost parts of the squirrel-cage rotor bars. As the rotor accelerates, the slip frequency declines, and current tends to travel deeper within the squirrel cage bars. Polyphase motors can generate torque from standstill, so no extra mechanism is required to initiate rotation. The different bar shapes can give usefully different speed/torque characteristics as well as some control over the inrush current at startup.
[edit]Linear induction motor
Main article: linear induction motor
A linear induction motor (LIM) is an AC asynchronous linear motor that works by the same general principles as other induction motors but which has been designed to directly produce motion in a straight line.
Linear motors frequently run on a 3 phase power supply.
Their uses include magnetic levitation, linear propulsion, and linear actuators. They have also been used for pumping liquid metals.[10